 The ceramic fuses used here are suitable for interrupting high currents at 100V DC (which, by the way, is not the case for 230V AC circuit breakers). The ceramic fuses used here are suitable for interrupting high currents at 100V DC (which, by the way, is not the case for 230V AC circuit breakers).
  
-=== DC/DC converter primary side driver ​and output relay ===+=== DC/DC converter primary side driver ===
  
 The circuit board within the 100V distribution box houses the driver that switches the primary side of the DC/DC converter. It is described in detail in chapter [[astra_conv:​conversion:​dcdc_converter:​dcdc_converter|DC/​DC converter]]. The circuit board within the 100V distribution box houses the driver that switches the primary side of the DC/DC converter. It is described in detail in chapter [[astra_conv:​conversion:​dcdc_converter:​dcdc_converter|DC/​DC converter]].
Line 58: Line 58:
 === DC/DC converter output relay === === DC/DC converter output relay ===
  
-The purpose of this relay (40A, in the drawing it is located at the top right of the box) has already been described in above subchapter ​[[#​dc_dc_converter_primary_side_driver_and_output_relay|]]+The purpose of this relay (40A, in the drawing it is located at the top right of the box) is described in chapter ​[[astra_conv:​conversion:​dcdc_converter:​dcdc_converter|DC/DC converter]].
  
  
Line 74: Line 74:
 === immobilizer relay === === immobilizer relay ===
  
-The little grey box above the main fuse is a relay that deactivates the motor controller in case the driver'​s door is opened ​or the tank lid is open. The relay is controlled ​by a circuit ​located in the rear distribution box, that also drives a warning beeper. This immobilizer function is required by ECE R-100 (only for the "open tank lid" case) to avoid that the car is moved while the charger cable is still connected. See also the similar requirement [[astra_conv:​conversion:​conversion#​sound indicates state of operation|]]. With the current setup, both conditions will trigger both beeper and immobilizer.+The little grey box above the main fuse is a relay that deactivates the motor controller in case the driver'​s door is openedthe tank lid is open or an isolation fault of the traction circuit against the chassis was detected 
 +These three alarm conditions are collected and relayed ​by the [[astra_conv:​conversion:​immobilizer:​immobilizer |immobilizer latch]] that is located in the trunk distribution box. 
 + 
 +This immobilizer function is required by ECE R-100 to e.g. avoid that the car is moved while the charger cable is still connected. See also the similar requirement [[astra_conv:​conversion:​conversion#​sound indicates state of operation|]]. With the current setup, both conditions will trigger both beeper and immobilizer. 
 + 
  
-Room for improvement:​ The immobilizer should not be allowed to engage any more once the car is moving. This would avoid the dangers of the car just stopping on the road just because of a broken door contact or a malfunction of the tank lid position sensor. 
  
 \\ \\